Multiwfn forum

Multiwfn official website: http://sobereva.com/multiwfn. Multiwfn forum in Chinese: http://bbs.keinsci.com/wfn

You are not logged in.

#1 2024-08-10 19:08:31

Heliumqt
Member
Registered: 2024-01-26
Posts: 3

Convergence Criterion Gaussian 16 C01 question

Dear Dr. Tien,

I am trying to perform a single point calculation on a large system using the M062x functional and def2-tzvpd basis set. However, I have tried every other convergence method (qc,xqc,yqc) etc and it did not work. However, I lowered the criterion to conver=6, and that seem to work. My question is would it be better if i set the criterion to conver=7 or conver=6 or conver=4? I am not as familiar with the default setting for single point in gaussian, and also not quite sure if increasing the number (hypothetically lets say convergence criterion in gaussian is conver=4) to conver=5 or conver=6, which of those two is less accurate or "relaxed" as compared to the default.

Offline

#2 2024-08-10 20:18:23

sobereva
Tian Lu (Multiwfn developer)
From: Beijing
Registered: 2017-09-11
Posts: 1,830
Website

Re: Convergence Criterion Gaussian 16 C01 question

If you just need to obtain electronic energy at a given structure, scf=conver=6 is acceptable for DFT calculation. Because when convergence threshold is reached in this case, usually energy has converged to <1E-7, which is fine enough.

PS: My given name is Tian

Offline

Board footer