Dear Dr. Tian Lu,
Please tell me why the calculated value of the Hessian lambda2 for critical points 121 and 190 is not negative if the value Sign(lambda2) * rho is negative? I understood correctly that lambda2 is the second Eigenvalues of Hessian?
Thank you in advance for your answers.
--
Best regards
Eugene
Last edited by Quark (2020-07-25 11:33:28)
Offline
Dear Eugene,
Please note that the eigenvalues of Hessian directly printed by Multiwfn are not ordered from most negative to most positive. If you reorder the eigenvalues for CP190 and CP121, you will find the second largest eigenvalues are negative. For example, the lambda2 of CP121 should be -0.02102 rather than 0.12423.
Best,
Tian
Offline
Dear Dr. Tian Lu,
Thank you very much for your help
--
Best regards
Eugene