Multiwfn forum

Multiwfn official website: http://sobereva.com/multiwfn. Multiwfn forum in Chinese: http://bbs.keinsci.com/wfn

You are not logged in.

#1 Re: Multiwfn and wavefunction analysis » Not ENough Storage? » 2020-08-07 02:17:56

Thanks for your suggestions.  I tried what you suggested with no success.
Thank you for looking into this.

#2 Multiwfn and wavefunction analysis » Not ENough Storage? » 2020-08-05 10:00:39

mzottola
Replies: 2

I generated a structure for the water dime at the MP2/6-31+g** level of theory.  I submitted this to MultiWFN v3.6 to analyze.  While MultiWFN was processing the file I received the following messages:
Loading various information of the wavefunction
Loading basis set definition...
Loading orbitals...
Converting basis function information to GTF information...
Generating density matrix...
Generating overlap matrix...
OMP: Error #136: Cannot create thread.
OMP: System error #8: Not enough storage is available to process this command.
OMP: Error #178: Function GetExitCodeThread() failed:
OMP: System error #6: The handle is invalid.

This is such a small system at such a modest basis set that I am having trouble believing my computer does not have adequate memory or disk space to handle it.  I regenerated the water dimer leaving out the set of diffuse functions, i.e. MP2/6-31g**.  When I submitted that file to MultiWFN, I received the same error.

The name of my file is wdimer.gms - and I cannot switch to version 3.7 as I am on a school computer that is still running Windows 7, 32-bit.  I can switch to my personal laptop but the bigger problem is why does a simple MP2 job cause such a problem with MultiWFN?  Can anything be done to get it to run on v3.6?

Thanks

#3 Multiwfn and wavefunction analysis » Cannot locate obvious BCP (3,-1) » 2019-10-18 07:59:39

mzottola
Replies: 1

I have a structure that  contains a hydrogen-chlorine bond.  However the program fails to find one despite find the 3,-3 critical points for both the hydrogen and the chlorine.  The interatomic distance is 1.37 angstroms making the lack of a bond critical point more of a software issue.  While this lack of a BCP may be due to an unusual electron topology, I am unaware how to test for that.

Is there any help or insight to help me locate this elusive point?

Thanks.

Board footer